0 . Unlike conventional plate readers, multimode microplate readers are able to perform two or more forms of detection allowing a single piece of equipment to perform a wider range of assays. Its software interface is easy to learn and use, and lets you control the instrument from almost any device – perfect for. The color touch screen provides a visual user interface, making programming fast and intuitive. $14,995. Cross-talk <0. 0 nm increments Dynamic range > 7 decades Cross-talk < 0. 2. Corning. d. \r Our multi-mode plate readers provide great flexibility and include absorbance, fluorescence and luminescence with configurable options for fluorescence polarization (FP), time. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. Can read 96 well plates (optional 384 well). Molecular Spectroscopy Consumables & Accessories Thermal Analysis. 90349). Contents of wells were pipetted up and down several times to mix. Max, FlexStation, Gemini, and earlier instruments as well as import and analysis of data files from FLIPR and Analyst instruments. Some will only support one well density (e. White 96-well plate Plate formats. We would like to show you a description here but the site won’t allow us. The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. A Costar 24-well tissue culture plate with col1 = blanks and doubling cell a list of plates specifically supported shows, 96, 384, 24, 12, 6 well types. Our microplate. 012 fmol 0. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. This eliminates the need for standard curves, and 96–well: 3 mP 384–well: 3 mP 1536–well: 6 mP 1 LUMI Glow luminescence detection for different plates 0200-7014POS Glow for 96-well plates 96–well: 1 pM 96–well: 1. Mix samples in microplate wells by user-programmable Automix feature. None for any other plate (6, 12, 24, 48 well plates) Flex3: Both Top read and Bottom read. Plate SpectraMaxiD3,iD5,i3x,i3,M2,M2e,M3,M4,M5,M5e,Plus. x. Ensure ongoing compliance of your Molecular Devices microplate readers and be audit ready with comprehensive . LogPhase 600 is controlled with a software App that provides a simple, yet powerful, user experience. Fluorescence Microplate Reader Comparison Chart. • Remove media from each well using a blue pipette tip being careful as not to remove cells. Cell line development teams will realize savings on time and resources, as well as faster time-to-market by utilizing a single technology for measuring a critical quality attribute duringOpening the Drawer Manually on page The SpectraMax ABS can accommodate standard 96-well plates. Self-righting base, up to 40 degrees past center without dispenser. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The Phosentix MicroQC™ Plate is an advanced microplate reader analysis tool that offers exceptional multi-modal functionality. 2. Fluorescence Microplate Reader Comparison Chart. Ultra-cooled Photomultiplier Tube and : Silicon photodiode. 00. For biochemical assays, the washer removes unbound material and unreacted reagents. Kinetic readings were started immediately with a Molecular Devices FlexStation Plate Reader. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. Here, we demonstrate that with Molecular Devices SpectraMax® microplate readers and the Quant-iT PicoGreen assay, users can reliably measure concentrations as low as 50 pg/mL of double-stranded DNA. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. The entire Bulk Kit is sufficient for 100 plates (96- and 384-well), or 70 plates (1536-well). The following detection cartridge is required: • Fluorescence Polarization (FP-FLUO) Detection Cartridge. 1. However, for greater flexibility, some instruments can accommodate 6- to 1536-well plate formats. When you do a read at wavelengths below 340 nm, you must use special UV-transparent, disposable or quartz plates to allow transmission of the deep UV spectra. Narrow bandwidths deliver increased accuracy and enhanced peak resolution. SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384. U-bottom: 30-40 µl. 5L) MultiWash+. No. No. Top and bottom reads are. The VersaMax Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible. 0 . Products : SpectraMax i3x reader, SpectraMax iD5 reader, SpectraMax iD3 reader, General, FilterMax F5 reader, SpectraMax ABS reader, SpectraMax L reader, SpectraMax M5/M5e reader. FlexIII. Specialized filters allow for IR fluorescence detection ranging from 10-40 times more sensitive than conventional monochromator detection reader. Shaking: Linear, orbital, and double orbital. Temperature control range from Ambient +4º to 50ºC. Microplate Capacity. Monthly Plate Verification Check (Absorbance Validation Plate) Note: Monthly Plate Verification Check is maintained by Quality Control. Get Quote . The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. Features of Streptavidin Coated Plates include: • Approximate binding capacity is ∼5 pmol biotin/well. is required for optimum performa nce with standard 96-well and 384-well format microplates for all top-read applications. The plate was preincubated in the reader at 37°C for a minimum of 10 minutes. Features: Standard back plate for use with hand sanitizer, hand lotion, or foam dispensers. The Gemini EM can sample a variety of formats, from 6- to 384-well microplates, in different modes, such as endpoint, spectral scan, kinetic, and well scan. Quartz 96 Well Plates | 96 Well Plate Flat Bottom | 96 Well Plate Reader | 96 Well Glass. #6590-0137) Optimal instrument settings for ValitaTiter (P/N VAL003 or VAL013, left table) and ValitaTiter Plus (P/N VAL004 or VAL014, right table) assays on the SpectraMax iD5 reader are shown below. x. Cross-talk <0. Each plate reader or washer is calibrated, inspected, and lubricated—any potential issues . Click SoftMax Pro Software User Guide. #E010) Pyroplate 96-well microplate (ACC cat. The EMax® Endpoint ELISA Microplate Reader from Molecular Devices, one of the pioneers in microplate detection, offers a ruggedly simple approach to dedicated endpoint assays. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. Products : Ionworks HT, Ionworks Quattro. Products : SpectraMax L reader How long does it take to dispense into a 96 well plate with SpectraMax L reader injection? For a 96-well plate it takes a total of 27. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. The perfect microplate reader for everyday biochemical assays, cell-based assays, molecular biology and immunoassays. These instruments deliver high precision and speed when reading 96 Well Microplates for single endpoint measurements and kinetic assay data gathered over time. Powerful, benchtop microplate stacker that works seamlessly with Molecular Devices microplate readers and washers. Locate the User Guide on your SoftMax Pro computer for version 6 and version 7. Standard features include a cuvette port, spectral scanning in 1 nm increments, and up to six wavelengths per read. Your applications, your modes, your choice. The Infinite 200 PRO is an easy-to-use multimode plate reader family that offers affordable, high performance detection solutions, referenced in more than 1800 peer reviewed publications. CO 2 & O 2 control. The EMax Endpoint ELISA Microplate Reader from Molecular Devices (one of the pioneers of microplate detection) provides a simple and durable dedicated endpoint detection method. Here, we demonstrate validation of the SpectraMax ® i3x Multi-Mode Microplate Reader for NanoBRET assays. a white 96-well half-area microplate (Corning cat. minutes and begin reading microplates with seven mouse clicks. Read the microplate • Make sure the purple plate adapter (if required for your plate reader) is in the microplate reader drawer. 000 to 2. In addition, the iD5 reader measures TRF and FP and. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. When a. 993 (Figure 3), validating the assay’s usefulness over a wide range of viable cell numbers. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. Devices® SPECTRAmax 190 microplate reader at a wavelength of 600 nm. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. Molecular Devices' microplate readers. Service parts for these models are not being produced and are no longer in stock. The EMax® Plus Microplate Reader delivers a robust solution in an entry level platform. 96- or 384-well microplate compatibility. 312 gain calibration failed. Title: SpectraMax i Series Multi-Mode Microplate Readers | Molecular Devices Author: Molecular Devices Subject: SpectraMax i Series offer the ideal solution for any application whether you are looking for an intuitive, easy-to-use reader, multi-user lab, or an upgradeable system that can adapt to support your lab s new projects. VMax . It offers extremely low absorbance background, excellent well to well uniformity, and zero percent cross talk. SpectraMax 250 User. Type:Single Mode Absorbance Plate Formats:96 well plates Accuracy:0. 000 OD ± 1. Pick the best speed, sensitivity, and price for your needs. With various on-board features and capabilities, the ThermoMax is ideal for use in modern laboratories involved in many applications. Only Molecular Devices microplate plate readers offer the capability to measure the depth (optical pathlength) of samples with no temperature dependency using the patented PathCheck® Sensor technology. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. At 5 seconds to read a 96-well endpoint assay or a 5 second minimum interval between kinetic reads, the VMax Microplate Reader has both speed and performance. To maximize sensitivity of the assay, it is necessary to use optimal excitation and emission wavelengths. Published Dec 16, 2020 | Updated Nov 07, 2022. where I 0 is the intensity of the incident light, and I is intensity of that light after it passed through the sample. Streamline multiple steps (imaging, sample tracking, data analysis and report generation) in the cell line development workflow for IND filing. x. Features of Clear 96-Well Microplates: • Clear plates for colorimetric ELISA and other assays. Browse for different fluorescent readers below and compare across different instrument suppliers. Compact design Minimum volume and maximum throughput with 96- or 384-well microplate compatibility Powerful data analysis with SoftMax® Pro Software Optimal performance with validation tools Small but Mighty EarlyTox Live/Dead Assay Kit (Molecular Devices cat. NanoQuant plate. We would like to show you a description here but the site won’t allow us. 46Click the Read button in the SoftMax Pro 8-channel (96) for FlexStation 3 Reader • 8-channel pipettor • (10) racks of 96-well, FlexStation Pipet Tips (Black) • 96-well yellow plate 0200-6182 Pipettor head kit, 16-channel (384) for FlexStation 3 Reader • 16-channel pipettor • (10) racks of 384-well, FLIPR® Tetra Pipet Tips (Clear) • 384-well yellow plate 0200-6183 Consumables ELISA Plate Readers / Microplate Readers. The trademarks used herein are the property of Molecular Devices, LLC or their respective owners. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow luminescence assays, including dual luciferase. Measurements for every well are automatically tracked over time. With various on-board features and capabilities, the ThermoMax is ideal for use in modern laboratories involved in many applications. Linear, Orbital Slow, and Orbital Fast. 0001 ABS (calculated) • Light source: Halogen lamp, 8V/50W • Wavelength range: 405, 450, 492, 630 nm, 4 more filters optional. Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Well scans from the Gemini EM Reader illustrating serial dilution of CHO cells using the Live Cell assay from Molecular Probes Live/Dead (Calcein AM/Ethidium Homodimer-1) assay kit. The Fluorometric Imaging Plate Reader (FLIPR®; Molecular Devices, Sunnyvale, CA) has made a significant contribution to drug discovery programs in the pharmaceutical industry since the first commercial instruments were introduced 9 yr ago. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. Detection cartridge modularity allows for easy addition of new read modes within minutes without. 340 PC384. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. The SpectraMax® i3x Multi-Mode Microplate Reader measures spectral-based . 6, 12, 24, 48, 96, 384-well plates : ANSI/SLAS Light source. M2. #i3x) SpectraMax L Microplate Reader (Molecular Devices cat. Quantitative, whole well cell confluence for every well. 2. x. This approach enables uniform light dose application to 9 wells (a 3-by-3 matrix in a 96-well plate) simultaneously, which can be leveraged to shorten the duration of PDT experiments (Fig. HeLa. No tools required to assemble. These models can no longer be repaired. The device was able to achieve 3σ limits of detection of ca. Microplate Reader Ordering information Item Description Part number FLIPR Membrane. Temperature control: 4°C above ambient to 45°C. 5 ng per well. 25, 3. Anticancer drug assay was also conducted using conventional 96-well plates as controls. Mix well by trituration or plate shaker and incubate for 2 to 5 minutes at room temperature, protected from light. #3603) SpectraMax ABS Plus Microplate Reader (Molecular Devices cat. They are also sealable using different types of adhesive mats foils or films. The SpectraMax ABS readers can be integrated with Molecular Devices StakMax® Microplate Stacker within . The reduced cost of the device represents the major technical contribution of this manuscript, as costs were reduced 7 fold from previous reports. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI). Technical specifications Performance specifications Cross-talk < 3 x 10-5 (96-well) Read modesplated at 50,000 cells/well in 100 µL of DMEM/FBS in a 96-well plate and incubated at 37°C for five hours. Important things to consider when purchasing a multimode microplate reader. Polypropylene deep well plates, round bottom. 000 ABS • Resolution: 0. 100 fmol 384-well (75 µL) 0. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. On the FlexStation 3 reader, the entire series of reactions is monitored in real time with simultaneous on-board reagent pipetting and luminescence detection (Figure 1). is required for optimum performa nce with standard 96-well and 384-well format microplates for all top-read applications. Wide photometric range Temperature-regulated Thermal control and vertical shake Microsoft Windows-based software Automatic mixing Five-second read per plate Photometric and kinetic analysis mode The Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. Page 20: Plate Adapter SpectraMax M3, M4, M5, and M5e Microplate Reader User Guide Plate Adapter Before you read standard 96-well or 384-well plates from the top, you must insert the plate adapter in. Published Dec 16, 2020 | Updated Dec 16, 2020. 00. With optimized reagents and the industry-leading data acquisition and analysis tool, SoftMax Pro® 7 Software, the SpectraMax® iD3. validation, maintenance, and repair documentation. ZERO BIAS - scores, article reviews, protocol conditions and moreThe VersaMax Absorbance Microplate Reader measures the optical density (OD) of samples at selected wavelengths in a number of reading modes. #25-340) Pyrogen-free Dilution Tubes (Lonza cat. A polyclonal antibody specific to mouse/rat IL-22 was pre-coated onto a 96-well microplate. with Quartz ABS Plastic. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. The SpectraMax® M3 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well…. This reader also makes use of a unique temperature-independent methodology for path length correction. In addition, users can define individual reagents and concentrations to be delivered to each well. Morphology and fluorescence gates were set to select the best 96 clones secreting IgG antibodies. The procedures in this protocol support the 96-well reaction plate. No accessories are needed and SoftMax® Pro Software. The VICTOR® Nivo™ system packs all popular detection modes into the industry’s smallest multimode reader footprint. This reader's dual monochromators for. Turn the instrument around so that the back of the instrument is. SpectraMax Paradigm Microplate Reader General specifications User-upgradeable Multi-Mode Detection Platform Technical specifications Optimized Guaranteed* Fluorescence Intensity (FI) (Fluorescein) 96-well (200 µL) 0. Wells of 96-well plates (NEST) were pre-coated with 100 μg/ml of collagen solution for 1 hour. UV absorbance detection. Dear Nelly, In a micro plate the fluorescence emission optics are very different from those in a single cell because of obstruction, reabsorption etc. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget-friendly solution with three modes of detection for UV-Vis absorbance, fluorescence, and luminescence. Now select the area of the plate to read. Description: Enter plate name (optional)(2) Wild‑type KRAS inhibits the migration and invasion of pancreatic cancer through the Wnt/β‑catenin pathway Molecular medicine reports January 1, 2023 Hu X, Zhang R, Yao J, Mu B, Zhao C. The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and comes with built-in absorbance, fluorescence, luminescence, time-resolved fluorescence (TRF), and tunable fluorescence polarization (FP) read modesRobust, high-value microplate readers that can run. For the 96-well plate, this equates to 1 fg per well to 1 ng per well; for the 384-well plate it is 0. measurements in compatible Molecular Devices® microplate readers. The reader adds up to three transfers of assay reagents from a 96- or 384-well source plate to enhance assay design using integrated fluidics. The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Microplate optimization and read height optimization were performed for best results. Molecular Devices’ SpectraMax® Plus 384 Microplate Reader provides fast and reliable full spectral range detection for cuvettes, 96-well and 384-well microplates. Selects either 96-well or 384-well plate for a stand-alone read. 0. x. A = 2 - log 10 (%T). The clear bottom plates offer the advantage of being able to examine the cells by microscopy during the course of the. 1 mL/well of media. Includes PC and software. Wavelength(s):. The SpectraMax® M3 Multi-Mode Microplate Reader provides three modes of detection in one platform. 001 ABS (displayed), 0. It has a 340-750nm Spectral Range. Microplates, cuvettes (via adapter) Detectors. Microplate Reader. Detection of KASP genotyping reactions. 5 fg per well to 0. REF (SpectraMax. Explore the best practices for running absorbance-based assays how Molecular Devices absorbance readers can be utilized to optimize said absorbance-based assays. Uncontrolled Copy for Training and Reference Purposes Only . Step 3: Click “Settings” and a screen will appear (Figure 1). and California) Microplate Spectrophotometer 100-240V ~ 4A 50-60 HZ T4. , Corning, NY) or Greiner. Usage/Application: Lab. Standard 6-, 12-, 24-, 48-, 96- and 384-well microplates. 384-WELL AND 96-WELL 10MM-HEIGHT STERILE MICROPLATES. You can use 6, 12, 24, 48, 96, and 384-well plates that conform to ANSI/SBS standard microplate footprint and dimensions in the instrument. to each well. Description Bottom Volume Qty/Pk Qty/Cs 3635 96 Well UV-Plate Flat 370 µL 2550per well of this semi-solid mixture was pipetted into 6-well plates. x. MultiWash+ for 96-well plates: 4 liquid lines, 8-way manifold and tubing, 4 wash/rinse bottles (2L), 1 waste bottle (2. Its software interface is easy to learn and use, and lets you control the instrument from almost any device – perfect for multiuser labs. For measuring the fluorescence or phosphorescence from a 6-, 12-,24-, 48-, or 96-well plate in either the X or Y direction or for luminescence micro densitometry of TLC plates and electrophoresis gels. x. The Gemini XPS Reader can be integrated with Molecular Devices’ StakMax ® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. UV-Star ® 96W Microplate, well working volume 25-370 μL; total well volume 392 μL. Top reading gives greater sensitivity for 96 well plates, unless you have cells adhering to the bottom of the well. Kinetic assays were read every 20-28 seconds for one hour,The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. $488. Ensure that cells reach around 80–90% of confluence on the day of the. Typically the system can detect absorbance, luminescence, fluorescence, and even make more specialized fluorescence measurements like time-resolved fluorescence (TRF) and fluorescence polarization (FP). These include real-time PCR, measuring yields of RNA preparations for microarray experiments, reverse transcription PCR (RT-PCR), differential display PCR,. A custom 96-well plastic (polyethylene terephthalate/PET) plate is attached via epoxy to the mounted CMOS ICs, designed with a standard form factor to be compatible with high-throughput. 01. flat-bottom: 50-60 µl. Before dispensing reagents to the microplate, the VersaMax Reader was powered on and SoftMax Pro GxP. The AquaMax® Microplate Washer is a fully self-contained system, configurable for both 96- and 384-well microplates. Luminometers and fluorimeters allow for readout of luminescence (luciferase readouts) or fluorescence from an entire well of a micro-well plate such as a 96- or 384-well plate. Visit the supplier page or submit a quote to learn more. Plate and Setup Rack Options Screens with selection of up to four Methods shown. After incubation of the cells with compounds, add 100 µL (for 96-well plates) or 25 µL (for 384-well plates) of Dye Solution per test well. Aspirating and dispensing of wash buffer can occur simultaneously in all wells via AquaMax® 4000 Microplate Washer with a 96-. 00 Add to cart; Molecular Devices EMax Microplate Reader $. PURPOSE. 2/24/2015 Molecular Devices FlexStation 3 Russ Desnoyer Our lab needed a way to measure Calcium flux downstream of the human AT1R receptor. 1 x plates; Instrument dimensions. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. This can increase throughput and efficiency, thus saving time and space in the lab. This 96-well assay has been fully validated on the SpectraMax iD5 reader and other Molecular Devices microplate readers with FP detection to ensure reliable results. Page 38 SpectraMax iD3 Multi-Mode Microplate Reader User Guide Bottle Holder The bottle holder is mounted on two knobs for ease of installation, cleaning, and replacement. Based on this customer experience and feedback, the Infinite 200 PRO microplate plate reader has been continuously engineered for. x. x. Flexible liquid transfer Using an 8- or 16-channel pipettor, the FlexStation 3 Reader offers added assay flexibility over dispenser-based systems by transferring reagents from 96 or 384 distinct wells in a source plate to a read plate, simultaneously. Each wellThe Molecular Devices ThermoMax is an efficient, temperature-regulated, 96 well microplate reader. 96-well PCR plates are plastic, heat-resistant multi-well microplates designed for use inside PCR machines or real-time (qPCR) thermocyclers. Consequently, FLIPR has been used. The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. The FlexStation® 3 Multi-Mode Microplate Reader can be used to run the SpectraMax DuoLuc assay in 96- and 384-well formats with high sensitivity and throughput. Fluorescence Microplate Reader Comparison Chart. Each well of a 96- well microtiter plate is coated with a fluorescently labeled IgG-binding peptide, Protein G. $3,450. FAST AND ACCURATE METERTECH Microplate Reader $3,650. The SpectraMax ABS/ABS Plus Microplate Readers provide fast absorbance detection without the use of filters with monochromator-based wavelength selection for visible and UV-visible absorbance. Accurate, efficient nucleic acid quantitation is critical for molecular biology labs that work with precious, rare, or difficult-to-process samples and applications requiring precise measurement. Resipher 96x Starter Kit for use with 96-well plates Includes: (1) Resipher Data Hub, (1) Resipher 96x Reader, (3) sterile sensing lids, all cables Turns a 96-well plate into a precise dynamic oxygen consumption reader, measures 96 wells Utilizes Lucid Lab Cloud software for connection to any…. Plate Storage Solutions for Liquid Handling Automation Remote Lab Management. Plate readers, also known as microplate readers or microplate photometers, are instruments which are used to detect biological, chemical or physical events of samples in microtiter plates. #3693; n = 4 for each standard). 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. . x. Place the microplate in the drawer. Suggested plates are black walled. Create custom fluorescence assays without having to purchase expensive filter sets. 3 OD at 200 nm. These robust readers have been placed in labs from. Plate types Flat and round 96-well plates Data output Export to PC Detection system Single channel silicon photodiode Reading speed 25 seconds Software SoftMax Pro Software Shaking None Temperature control None Linearity 0. Populate the following info under Description. 100 uL of LAL reagent was then added to the wells containing the endotoxin standards, and the kinetic read was started. FlexStation® 3 Benchtop Multi-Mode Microplate Reader combines Molecular Devices’ SpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact benchtop reader. Two different agonists, acetylcholine and carbachol, were tested. The onboard luminescence detection mode may be used, or, for higher sensitivity, the reader can be equipped with a NanoBRET detection cartridge that offers a 4-fold improvement in limit of quantitation. Related products. The soil was amended with either 1. Use standard plate unless you see your type listed. Microplate Readers. Absorbance was then determined at 450 nm by SpectraMax Paradigm microplate reader (Molecular. ₹ 1,80,000 Get Latest Price. #C1500) Control standard endotoxin (ACC cat. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. The eight-channel system delivers high precision and speed when reading 96-well microplates for single endpoint measurements and kinetic assay data gathered over time. View Product. Deep well blocks available in 24, 96 and 384-well formats An affordable, tunable microplate reader for 96-well format Affordable The robot-compatible VersaMax reader is cost-effective—users never have to buy filters. A standard curve consisting of MCF7 cells seeded from 20 to 20,000 per well in a 96-well plate was linear across the entire range with r 2 = 0. 2. Figure 2-23: Bottle holder To install the bottle holder: 1. Cayman Chemical. Gemini EM Reader scans. Published Dec 16, 2020 | Updated Dec 06, 2021. for molecular biology. 130009WMicroplate Readers. This is a Molecular Devices Thermomax 96 well Absorbance Microplate Readers. The SpectraMax® M2 and M2e Systems from Molecular Devices are multi- detection microplate readers with dual- monochromators, dual-mode cuvette ports, and top- and. NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. Packed 25 plates per sleeve, 2 sleeves per case. Gemini XPS & EM readers measure fluorescence on a variety of sample formats from 6- to 384-well microplates. Gemini XPS and EM Microplate Readers with dual monochromator fluorometers provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Enable more assay conditions Define individual reagents to be delivered to each well reducing reagent consumption and allowing for more assay conditions to be explored on a single microplate. SpectraMax i3x Multi-Mode Microplate Reader. 1 - 32 of 54 Sort View Show > Well Plate Reader Accessory PerkinElmer For measuring the fluorescence or phosphorescence from a 6-, 12-,24-, 48-, or 96-well plate in either the X or Y direction or for luminescence micro. Transfer the assay plate directly to a bottom-read fluorescence microplate reader for kinetic read-mode or incubate for 10-30 min at 37oC and then read for endpoint read-mode. Range of 96, 384-well SBS microplates . 96-, 384-, and 1536-well microplates. Gemini XPS and EM Microplate Readers with dual monochromator fluorometers provide a flexible environment to determine the optimal excitation and emission settings for fluorescence intensity assays. Optional 12-way manifold) 5032336. A microplate adapter is required in the reading chamber drawer for 96- and 384-well assay plates. SoftMax Pro GxP Software version 5. . 300 µL of Detergent Compatible Bradford reagent was added to each well. SpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers User Guide — 0112-0102 Rev. 305 reference level saturation. 5 mm left a residual volume of 100 µL in each well of a 96-well plate or 25 µL for a 384-well plate. VMax . The SpectraMax ABS Plus reader was heated to 37ºC prior to setting up the assay. 6-384 (96- and 384-well with pipetting) 96-well microplates. The ultimate guide to microplate readers is an eBook that tells you everything you need to know about plate reader solutions from what a microplate reader is, to popular applications and technology, to GxP compliance and special tips and tricks to help maximize your. Fluorescence, Absorbance Fastest Read Time - 96-well plate: 20 sec; 384-well plate: 30 sec Temperature Control: Ambient +5C up to 42C Shaking: Linear and Orbital. First choose Read Mode ‘FL’ and Read Type ‘Endpoint’, and then select. EMax. adjust the reader. An entire 96-well plate can be processed in less than six seconds. #R8195. The UV-Plate is compatible with the following plate readers: Bio-Tek PowerWave™ 200 Bio-Tek µQuant™ BioRad UltraMark™ Molecular Devices SPECTRAmax® 190, 250, 340PC, and Plus Ordering Information Cat. Calcium flux was measured with a FlexStation 3 Microplate Reader using the Flex (fast kinetic) read type. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M5e Microplate Reader transforms each well in a microplate to a fixed. To test the optical clarity of the various microplates at low wavelengths, one well of each plate was filled with 100 μL (96-well) or 20 μL (384-well) distilled water, and its. Tecan’s quality control and validation packages help our customers to fulfill all regulatory requirements for their Tecan microplate readers in an efficient, cost-effective way. The FilterMax™ F3 features absorbance (visible), fluorescence intensity - FI (top reading), and glow luminescence for 96- to 384-well plates. Products : General, FilterMax F5 reader. The ELx808 TM Reader seamlessly interfaces with Lonza's WinKQCL TM Endotoxin Detection and Analysis Software. 200, the Bio-Tek µQuant™, the Bio-Rad UltraMark™, the Molecular Devices SPECTRAmax® 190 and 250 plate readers. With the QuickSync client installed on your computer, your SpectraMax iD3 reader can push data to any computer within the same network. x. A = Log 10 (I 0 /I). 4 (Molecular Devices cat.